Nib F/S Euchner CES-A-AEA-04B / CESAAEA04B and 48 similar items
NIB F/S EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000
£525.81 GBP
View full item details »
Shipping options
Offer policy
OBO - Seller accepts offers on this item.
Details
Return policy
Full refund available within 30 days
Purchase protection
Payment options
PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted
View full item details »
Shipping options
Offer policy
OBO - Seller accepts offers on this item.
Details
Return policy
Full refund available within 30 days
Purchase protection
Payment options
PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted
Item traits
Category: | |
---|---|
Quantity Available: |
Only one in stock, order soon |
Condition: |
New |
MPN: |
CES-A-AEA-04B |
Country/Region of Manufacture: |
Germany |
Type: |
Safety Relay |
Order No.: |
072000 |
Brand: |
EUCHNER |
UPC: |
Does not apply |
Listing details
Shipping discount: |
Shipping weights of all items added together for savings. |
---|---|
Posted for sale: |
More than a week ago |
Item number: |
1042359628 |
Item description
NIB F/S EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000
4 read heads can be connected
2 safety contacts (relay contacts)
1 internal normally open contact per safety contact
Start button and feedback loop can be connected
Unicode evaluation unit
Category 4/PL e according to EN ISO 13849-1
Mechanical values and environment
Housing material
Housing
Plastic PA6.6
Weight
Net
0,25 kg
Ambient temperature
At UB = 24V DC
-20 ... 55 C
Atmospheric humidity
Not condensing
max.80 % rH
Degree of protection
IP20
Mounting method
Mounting rail 35mm according to DIN EN 60715 TH35
Mounting distance
Sideways toward the neighboring device
min.10 mm
Number of read heads
Max. 4 read heads can be connected.
Ready delay
10 ... 12 s
Reaction time
After change in the actuation status, 2 active actuators
max.290 ms
Duration of operation start button (for Manual start operating mode)
min.250 ms
After change in the actuation status, 1 active actuator
max.210 ms
After change in the actuation status, 4 active actuators
max.450 ms
After change in the actuation status, 3 active actuators
max.370 ms
Response delay start button (for Manual start operating mode)
200 ... 300 ms
Switching frequency
max.0,25 Hz
Dwell time
min.3 s
Connection
Screw terminals
Safety contacts 13/14, 23/24
Number of safety contacts
2 Relays with internally monitored contacts
Mechanical life
Operating cycles (relay)
10 x 106
Electrical connection ratings
Operating voltage DC
UB
21 ... 24 ... 27 V DC Regulated, residual ripple 5 %
Current consumption
(with relay energized)
150 mA
Fusing
External (operating voltage UB)
0,25 ... 8 A
EMC protection requirements
In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)
2
Connection cross-section
(screw terminals)
0,25 ... 2,5 mm
Current via feedback loop
5 ... 8 ... 10 mA
permissible resistance in feedback loop
max.600 ?
Safety contacts 13/14, 23/24
Type of output
Relay contacts, floating
Switching current
At switching voltage AC/DC 17 ... 30 V
15 ... 6000 mA
At switching voltage AC/DC 1 ... 60 V
1 ... 300 mA
At switching voltage AC 17 ... 230 V
15 ... 1500 mA
Fusing
External (safety circuit) according to EN 60269-1
6 AgG or 6 A circuit breaker (characteristic B or C)
Utilization category acc. to EN 60947-5-1
AC-15
230 V 1.5 A
DC-13
24 V 1.2 A
AC-12
30 V 6 A
60 V 0.3 A
DC-12
60 V 0.3 A
30 V 6 A
Switching load
According to c UL us
Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
Rated insulation voltage Ui
250 V
Rated impulse withstand voltage Uimp
4 kV
Rated conditional short-circuit current
100 A
Discrepancy time
(Between the operating points of both relays, with 4 active actuators)
max.400 ms
STATE LED
LED indicator
Status LED
LED OUT
LED indicator
Safety outputs status
DIA LED
LED indicator
Diagnostics LED
Monitoring outputs: Diagnostic DIA, door monitoring outputs O1,O2,O3,O4
Type of output
Semiconductor output, p-switching, short circuit-proof
Output voltage
0,8 x UB ... UB V DC
Output current
max.20 mA
Inputs: Start button S, test input TST
Input current
HIGH
5 ... 8 ... 10 mA
Input voltage
LOW
0 ... 2 V DC
HIGH
15 ... UB V DC
Work area
Repeat accuracy R
According to EN 60947-5-2
max.10 %
Other
For the approval acc. to UL the following applies
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
PFHD at = 0,1 A
1.3 x 10-8
PFHD at = 3 A
1.5 x 10-8
(description exceeds maximum possible length)
Why are we showing these items?
Booth
premiumplc's booth |
![]() |

-
Refine your browsing experience
We can show you more items that are exactly like the original item, or we can show you items that are similar in spirit. By default we show you a mix.
This item has been added to your cart

View Cart or continue shopping.



Get an item reminder
We'll email you a link to your item now and follow up with a single reminder (if you'd like one). That's it! No spam, no hassle.
Already have an account?
Log in and add this item to your wish list.