Quality items from Bonanza’s top-rated sellers.

premiumplc's booth earned a 99.8% satisfaction rating for providing an excellent experience from start to finish. View booth >>

Rendered at 10:35:02 04/28/25
Full-size item image
Primary image for NIB F/S EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000
Item image 1
Item image 2
Item image 3

NIB F/S EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000

£525.81 GBP
Ships from United States Us

Don't miss out on this item!

There is only 1 left in stock.

Shipping options

Estimated to arrive by Mon, May 5th. Details
Calculated by UPS in GB.
Ships from United States Us

Offer policy

OBO - Seller accepts offers on this item. Details

Return policy

Full refund available within 30 days

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Shipping options

Estimated to arrive by Mon, May 5th. Details
Calculated by UPS in GB.
Ships from United States Us

Offer policy

OBO - Seller accepts offers on this item. Details

Return policy

Full refund available within 30 days

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Item traits

Category:

Safety Relays

Quantity Available:

Only one in stock, order soon

Condition:

New

MPN:

CES-A-AEA-04B

Country/Region of Manufacture:

Germany

Type:

Safety Relay

Order No.:

072000

Brand:

EUCHNER

UPC:

Does not apply

Listing details

Shipping discount:

Shipping weights of all items added together for savings.

Posted for sale:

More than a week ago

Item number:

1042359628

Item description

NIB F/S EUCHNER CES-A-AEA-04B / CESAAEA04B UNICODE EVALUATION UNIT 072000 4 read heads can be connected 2 safety contacts (relay contacts) 1 internal normally open contact per safety contact Start button and feedback loop can be connected Unicode evaluation unit Category 4/PL e according to EN ISO 13849-1 Mechanical values and environment Housing material Housing Plastic PA6.6 Weight Net 0,25 kg Ambient temperature At UB = 24V DC -20 ... 55 C Atmospheric humidity Not condensing max.80 % rH Degree of protection IP20 Mounting method Mounting rail 35mm according to DIN EN 60715 TH35 Mounting distance Sideways toward the neighboring device min.10 mm Number of read heads Max. 4 read heads can be connected. Ready delay 10 ... 12 s Reaction time After change in the actuation status, 2 active actuators max.290 ms Duration of operation start button (for Manual start operating mode) min.250 ms After change in the actuation status, 1 active actuator max.210 ms After change in the actuation status, 4 active actuators max.450 ms After change in the actuation status, 3 active actuators max.370 ms Response delay start button (for Manual start operating mode) 200 ... 300 ms Switching frequency max.0,25 Hz Dwell time min.3 s Connection Screw terminals Safety contacts 13/14, 23/24 Number of safety contacts 2 Relays with internally monitored contacts Mechanical life Operating cycles (relay) 10 x 106 Electrical connection ratings Operating voltage DC UB 21 ... 24 ... 27 V DC Regulated, residual ripple 5 % Current consumption (with relay energized) 150 mA Fusing External (operating voltage UB) 0,25 ... 8 A EMC protection requirements In acc. with EN 60947-5-3 Degree of contamination (external, according to EN 60947-1) 2 Connection cross-section (screw terminals) 0,25 ... 2,5 mm Current via feedback loop 5 ... 8 ... 10 mA permissible resistance in feedback loop max.600 ? Safety contacts 13/14, 23/24 Type of output Relay contacts, floating Switching current At switching voltage AC/DC 17 ... 30 V 15 ... 6000 mA At switching voltage AC/DC 1 ... 60 V 1 ... 300 mA At switching voltage AC 17 ... 230 V 15 ... 1500 mA Fusing External (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C) Utilization category acc. to EN 60947-5-1 AC-15 230 V 1.5 A DC-13 24 V 1.2 A AC-12 30 V 6 A 60 V 0.3 A DC-12 60 V 0.3 A 30 V 6 A Switching load According to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp 4 kV Rated conditional short-circuit current 100 A Discrepancy time (Between the operating points of both relays, with 4 active actuators) max.400 ms STATE LED LED indicator Status LED LED OUT LED indicator Safety outputs status DIA LED LED indicator Diagnostics LED Monitoring outputs: Diagnostic DIA, door monitoring outputs O1,O2,O3,O4 Type of output Semiconductor output, p-switching, short circuit-proof Output voltage 0,8 x UB ... UB V DC Output current max.20 mA Inputs: Start button S, test input TST Input current HIGH 5 ... 8 ... 10 mA Input voltage LOW 0 ... 2 V DC HIGH 15 ... UB V DC Work area Repeat accuracy R According to EN 60947-5-2 max.10 % Other For the approval acc. to UL the following applies Reliability values according to EN ISO 13849-1 Monitoring of the safety guard position PFHD at = 0,1 A 1.3 x 10-8 PFHD at = 3 A 1.5 x 10-8 (description exceeds maximum possible length)